6.2 Preparing for operation
6 Commissioning
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
6-4
6.2.2.2 Connect incremental encoder to the speed monitor via an adapter
Connect incremental encoder to the speed monitor via an adapter6-Drehzahlwaechter_Betriebsb_Inkremen_ueber_Adapt_HTL_BA
The adapter (e.g. PNOZ msi6p) is connected between the incremental
encoder and the drive. The output on the adapter is connected to the
RJ-45 female connector on the speed monitor.
The adapter can also be used without connecting to a drive.
The signals relevant for the speed monitor are utilised in parallel by
the adapter. The information stated in section 6.2.2.1 and in the
adapter operating manual must be observed when connecting the
supply voltage.
Supply voltage (12 V – 30 V) to incremental encoder only.
HTL signals may not be fitted with a terminating resistor.
Fig. 6-4: Connection via adapter and drive
Incremental
encoder
A
/A
B
/B
X12
X22
Speed monitor
Drive
Adapter
24 V
0 V
24 V DC
0 V
18