Example
} Inductive load: 0,2 A
} Utilisation category: AC15
} Contact service life: 2,000,000 cycles
Provided the application requires fewer than 2,000,000 cycles, the PFH value (see techni-
cal details) can be used in the calculation.
To increase the service life, sufficient spark suppression must be provided on all output
contacts. With capacitive loads, any power surges that occur must be noted. With contac-
tors, use freewheel diodes for spark suppression.
Technical Details
General 750102 751102
Approvals CCC, CE, GOST, KOSHA, TÜV,
cULus Listed
CCC, CE, GOST, KOSHA, TÜV,
cULus Listed
Electrical data 750102 751102
Supply voltage
Voltage 24 V 24 V
Type DC DC
Voltage tolerance -15 %/+10 % -15 %/+10 %
Output of external power supply
(DC)
2,0 W 2,0 W
Residual ripple DC 20 % 20 %
Continuous duty 100 % 100 %
Max. inrush current impulse
Reset circuit 0,50 A 0,50 A
Feedback loop 0,50 A 0,50 A
Max. overall cable resistance Rl-
max
Single-channel at UB DC 30 Ohm 30 Ohm
Voltage at
Input circuit DC 24,0 V 24,0 V
Reset circuit DC 24,0 V 24,0 V
Feedback loop DC 24,0 V 24,0 V
Current at
Input circuit DC 75,0 mA 75,0 mA
Reset circuit DC 7,0 mA 7,0 mA
Feedback loop 7,0 mA 7,0 mA
Number of output contacts
Instantaneous safety contacts
(N/O)
3 3
Auxiliary contacts (N/C) 1 1
Inputs 750102 751102
Number 1 1