4.1 Overview
4 Function description
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
4-4
Fig. 4-3: Definitions
Key:
1: Light beam bundle
2: Illuminated target area
3: Protected field
4: Detection zone
Funktion_Schutzfeld_allgemein
The shape and size of the protected field depend on the bending func-
tion and the machine-dependent overrun. A reduced protected field is
possible for box bending and/or back gauge mode (for the size of the
protected field please see "Protected field" section and the chapter en-
titled "Technical Details").
If an object encroaches into the detection zone, both output signal
switching devices (OSSD1 and OSSD2) on the PSENvip will switch to
the OFF-state. The safety system will use these signals to initiate stop-
ping of the press stroke.
1
2
3
4