4 Function description
4.2Protected field4200Protected field4-Funktion_Schutzfeld
The protected field consists of several segments. The front and rear seg-
ments (viewed from the operator's side) can be deactivated. This pro-
vides flexibility to adapt to the bending function:
Standard
Full protected field: all segments active
Box bending
Reduced protected field: front segments deactivated
Bending with back gauge
Reduced protected field: rear segments deactivated
Box bending with back gauge
Reduced protected field: front and rear segments deactivated
Fig. 4-4: Protected field definitions
Funktion_Schutzfeld_Groesse
The height of the protected field depends on the overrun. For the setting
range of the overrun please see following figure and Chapter 11, "Tech-
nical Details".
Fig. 4-5: Size of the detection zone
Funktion_Schutzfeld_Info_Kastenbiegen
44
max. 20
min. 8
6
1
Overrun distance 2 m
Overrun distance 14 mm