6-5
6.2 Connections
6 Wiring
*) Used in communication between PSENvip and safety system.
Pin assignment of M12 connector X2 on the receiver
*) Used in communication between PSENvip and safety system.
Verdrahtung_Anschluss_Empfänger_OSSD
The two safety outputs OSSD1 and OSSD2 must be connected sepa-
rately to the machine's programmable safety system. OSSD1 and
OSSD2 must not be connected.
Fig. 6-4: Correct and incorrect connection of OSSD1 and OSSD2
8 TRM_ON Output, signal to switch the transmitter's light
source on and off
Red
Shield Cable shield
PIn No. Designation Description Colour
1 Overrun measurement 2 Output, result of overrun measurement White
Tool class PSENvip -> PLC Bit 2
*)
Output, sends tool class Bit 2 to safety system
2 Power Off Input, activates setup mode Brown
PLC Ready *) Input, safety system signals that it is ready for com-
munication
3 Acknowledgement Input, acknowledges initiation of a press stroke with
reduced protected field
Green
4 System-Init Input, the press is at top dead centre Yellow
5 OSSD2 Output, OSSD2 Grey
6 Acknowledge PSENvip -> PLC *) Output, confirm validity of tool class Pink
7 0 V Input, 0 V supply voltage Blue
8 TRM_SYNC Output, signal to control the intensity of the trans-
mitter's light source
Red
Shield Cable shield
PIn No. Designation Description Colour